| Fan speed: boost and run-on from condensation risk< 10 s · comfort and damp call, not a safety call; wall pixel ± 1.5 °C (MLX90640 typical) | The equipment | SHT45 humidity, wall heat camera, radar; dew point of the room air against the coldest wall pixel; run on until the margin is back above 3 °C | Fan speed shown as a soft white glow on the grille. The pull cord or app always overrides; if the wall camera is unsure (steam on the window), it runs on room humidity like a plain humidistat fan |
| Condensation and mould risk on the outside wall, ceiling or windowevery 30 s; hours counted daily · surface RH about ± 5 % (est.) | The equipment | wall heat camera, SHT45; surface humidity per pixel from the room dew point; mould-risk hours above 80 % surface RH | Amber glow and a short tone when a corner stays wet; weekly damp record in the app. Under 80 % confidence (a towel or a person in front of the wall): unsure, the hour is not counted |
| Water on the floor< 2 min after the patch reaches about 20 cm · about 90 % of spills larger than 20 x 20 cm (est.); smaller puddles may be missed | The equipment | floor heat camera, mic, radar; a cool patch spreading on the floor (evaporation) that is not a person's footprint or a bath mat, plus drip or flow sound; int8 classifier | Blue light and fast tone at the grille, then an alert to the family. Under 85 % confidence (a wet mat after a shower): unsure, heat clip to the app, no alarm |
| Tap left running or bath about to overflow< 1 min after the limit · about 92 % (est.) | The equipment | mic, floor heat camera, radar; running-water sound with a warm, rising water surface in the bath or basin and the room empty past a limit (default 8 min) | Blue light and tone, then the family alert. Someone in the room: no call; sound with no warm water seen: unsure |
| Washer cycle done, or a leak during the cycle< 2 min · about 95 % of cycles (est.) | The equipment | mic, floor heat camera; spin and drain sound pattern (CycleTap) and a cool patch at the washer front | Green light for 'done', blue light and tone for a leak. A pattern it does not know is logged, not announced |
| Someone still in the bathroom with no movementat the limit · about 90 % (est.) | Helps the official | radar, floor heat camera; presence with no movement past a limit the family sets (default 30 min); not a fall detector | Amber glow and a gentle chime first, then the family alert. Alert only; the family decides whether to call; the person can wave to cancel |
| Window left open in the cold, or heating off in a damp weekhourly · about 85 % (est.) | Helps the official | wall heat camera, SHT45; glass and wall temperature trend against the outdoor forecast | App note, no light. Info only |
| Bathroom kept below 18 °C for long hours in the cold season (cold record)daily summary · room temperature ± 0.1 °C typical (Sensirion SHT45 datasheet); cold hours about 90 % (est.) | Helps the official | SHT45 room temperature, wall heat camera; hours below 18 °C (WHO housing guideline) with the outside wall temperature, outside the hour after a shower or an open window | App note and a line in the signed damp record, no light. Window open or heating off already flagged: noted as the reason, no cold note |