Skip to content
IEMI Labs
All product designs
SensingDesign rev A, 27 Oct 2026: CAD, fit checks and assembled 3D model done; not built

GuestRoom

One ceiling node per guest room: smoke and vape evidence, AC set back when the room is really empty, and a damp bathroom wall caught early

One ceiling disc in each hotel, rental or serviced-apartment room does three jobs with one brain: it records smoke and vape events with evidence, sets the wall AC back by its own remote codes when a radar says the room is really empty (and uses dry mode instead when the bathroom wall is damp), and warns housekeeping when the bathroom's coldest wall stays at mould-risk humidity.

Who buys it
Owners and managers of small and mid-size hotels, motels, serviced apartments and short-term-rental hosts with wall split or ductless ACs.
Why it pays
Minut puts a hotel smoking incident at $620–1,300; occupancy setback reported nearly $180 a room a year at two Wisconsin hotels (vendor-reported); mould remediation runs $500–10,000+ a room plus nights out of order (trade press). For one room GuestRoom is $329 + $8/month instead of about $547 + $13.50/month for our three products separately.
Target price
$329 per room + $8/room/month (target)
First-minute wow
At 14:10 the room has been empty for 20 minutes, so the AC goes to 26 °C; the bathroom wall is at 78% surface humidity, so it runs dry mode instead of switching off; at 22:14 the same disc records a vape with a curve the guest can be shown.
GuestRoom concept: the idea and where each part goes
The concept. The CAD design is below, under Printable CAD.

What the research found

And how this design answers it

  • Three products, three boxes, three apps (AirMate IR, VapeSense, MouldGuard) → one ceiling disc with one ESP32-C6, one Wi-Fi link, one USB-C supply and one app
  • AirMate IR's own ESP32-C6, SHT45 and case → a small AC pod with no processor beside the disc, on a 6-core lead
  • MouldGuard needed its own hub → its wall tag runs on a flat cable over the bathroom door to the disc
  • Empty-room setback can make a humid room damp → the node uses the AC's dry mode instead of off when the wall is at mould risk
  • VapeSense's LoRa radio and building gateway → not fitted; hotels and hosts use their own IoT Wi-Fi
  • Housekeeping overrides undo occupancy savings (BPA study) → radar sees still guests, and the guest's own remote is heard and respected

Use case

A summer day in room 214

Hotel managerHousekeepingGuestGuestRoom node

  1. 01Trigger: the guest leaves at 13:50 with the AC on 20 °C; the radar sees nobody, not even someone still in bed
  2. 02Decide: after 20 minutes empty the node would set the AC back, but the bathroom wall tag reads 78% surface humidity
  3. 03Act: the pod sends the AC's own dry-mode code at 26 °C; when the guest comes back at 18:30 it restores 20 °C
  4. 04Evening: at 22:14 a vape event is classified with an evidence card; housekeeping gets a damp-wall note for room 214 the next morning

Outcome: About 4.5 AC hours set back (est.), a wall that dried instead of growing mould, and a smoking fee backed by a record, from one device

How it works

Architecture

  1. 01

    Sense: Sensirion SEN66 + Bosch BME690 in the disc; HLK-LD2410C radar and a TSOP38238 in the AC pod; SHT45 + NTC in the bathroom wall tag

  2. 02

    Decide: one ESP32-C6 runs the VapeSense classifier, AirMate's empty-room state machine and MouldGuard's surface-humidity rule

  3. 03

    Act: four TSAL4400 IR LEDs send the AC's own remote codes

  4. 04

    Tell: Wi-Fi 6 on the owner's IoT network, MQTT over TLS to one GuestRoom app with events, AC hours and damp trends

Hardware

Real parts, buyable today

Bill of materials: about $116 per room at qty-1 prices including the adapter (est.).

BlockPartWhy this part
BrainEspressif ESP32-C6-MINI-1 on the VapeSense disc PCBAlready ran the vape classifier; has room for the AC and damp rules and Wi-Fi 6
AirSensirion SEN66 + Bosch BME690Smoke and vape evidence; the SEN66 also gives the room humidity the damp rule needs
PresenceHi-Link HLK-LD2410C 24 GHz radarSees still guests, so the AC is never set back on a sleeping guest
AC control4 × Vishay TSAL4400 + TSOP38238Works any split, window or portable AC with its own remote codes
DampSensirion SHT45 + TDK B57861S NTC wall tagThe wall's surface humidity is the mould risk, not the room's
PowerUL-listed 5 V USB-C adapter + 1 F supercapNo mains in printed parts; a last 'power lost' message

Mechanical

Printable CAD

8 parts, generated from code and checked as closed solids. Pick a part to inspect it, or download the STL files to print.

Loading the CAD…

Real CAD · drag to rotate · scroll to zoomReal CAD · swipe sideways

Open risks we are working on

  • Radar through a 0.9 mm lid from the ceiling must be proven to see a still guest in bed and not the AC's moving louvres
  • IR from the ceiling pod must reach the AC's receiver; a second pod angle or a reflector may be needed in long rooms
  • Shower steam reaching the disc must not be called a vape; the BME690 and RH rules are from VapeSense and unproven
  • The wall tag's cable over the bathroom door must be neat enough for a hotel; a battery BLE tag is the fallback
  • Smoking evidence and fees need a policy the guest agreed to; the node gives evidence, the manager decides
  • Energy savings depend on the AC, the climate and guests; vendor figures vary and one independent study found less

Design stage only: nothing on this page is for sale. Specifications and prices are targets.