IndustrialDesign complete (stages 1–6, rev A), not built, not validated

AirLeak

What your compressed-air leaks cost, measured at the compressor every weekend

Measures how hard your compressors work when the plant is idle and turns it into a weekly dollar figure for leaks, so you know when a leak hunt is worth doing and whether the last one held.

Who buys it
The plant manager or maintenance lead at a small plant with 1–3 screw compressors of any brand; compressed-air service shops resell it.
Why it pays
Example 50 hp plant idling at 40% load: about $9,000/yr of leaks; bringing it to 15% is worth about $5,600/yr (est.).
Target price
$590 kit + $19/site/month; extra compressor CT $79; handheld probe $179 (target)
First-minute wow
A Monday email that says "Idle air last weekend: $175, $9.1k/yr pace, up 12% since your September survey", with the method and its confidence shown.
AirLeak concept: the idea and where each part goes
The concept. The CAD design is below, under Printable CAD.

What the research found

And how this design answers it

  • MEMS mics can't locate leaks in a noisy plant at 80 kHz → no fixed acoustic array; leak quantity is measured at the compressor (current) and header (pressure)
  • Atlas Copco SMARTLINK is free for Atlas machines → brand-agnostic clamp-on retrofit for any compressor, including old relay-controlled ones
  • Leak savings were estimates → the weekend figure is the DOE/CAC load-unload measurement (T/(T+t)), run automatically every weekend
  • Handheld ultrasonic detectors cost $3,495+ → optional $179 40 kHz heterodyne probe for walking a valve bank at 1–3 m
  • Flow meters ($625+) give cfm, not dollars → works without one; accepts a 4–20 mA meter for VSD compressors
  • Surveys are one-off → before/after reports prove a repair day paid and alert when leaks creep back

Use case

The weekend leak bill

Plant managerMaintenance techCompressed-air service shop

  1. 01Trigger: Saturday to Monday, no production, the compressor keeps loading and unloading
  2. 02Detection: the node times every loaded and unloaded interval from the current clamp; the cloud computes 40% idle load ≈ 84 cfm
  3. 03Alert: Monday email with $175 this weekend, $9.1k/yr pace and a 12-week trend
  4. 04Action: the tech walks the plant with the probe, tags 20 leaks, fixes 15; next weekend's report shows the drop

Outcome: Idle load from 40% to about 15%: about $5,600/yr saved (est.)

How it works

Architecture

  1. 01

    Sense: 200 A split-core CT per compressor (0.333 V), 0–200 psi header transducer, optional 4–20 mA flow meter

  2. 02

    Decide (node): ESP32-S3 + ADS131M04 classify each compressor as off, unloaded, loaded or VSD every second

  3. 03

    Send: 60 s telemetry and state events over MQTT/TLS on Wi-Fi, 7-day flash buffer

  4. 04

    Decide (cloud): quiet-window detection, leak % by load/unload, drawdown or flow method, kW and $

  5. 05

    Tell: Monday report, web dashboard, phone app with probe survey and leak list

Hardware

Real parts, buyable today

Bill of materials: about $392 per node kit at qty 1 (transducer $273), about $215 at qty 60 (est.); probe about $30 of parts.

BlockPartWhy this part
MCU + Wi-FiESP32-S3-WROOM-1-N8R8Wi-Fi, PSRAM for a 7-day buffer, $6.13
ADCTI ADS131M04 24-bit 4-ch simultaneousReads 0.333 V CTs and pressure directly
CurrentMagnelab SCT-1250-200 split-core CTClamp-on, low-voltage output, up to ~150 hp at 460 V, $44.52
PressureHoneywell PX3AN2BS200PSAAX 0–200 psiIndustrial 1/4" NPT, 0.5–4.5 V; drawdown tests
ProbeMurata MA40S4R + NXP SA612A heterodyne + ESP32-C340 kHz leak hiss to headphones plus BLE level, for under $40 of parts

Mechanical

Printable CAD

8 parts, generated from code and checked as closed solids. Pick a part to inspect it, or download the STL files to print.

See the CAD parts render
AirLeak printable parts, rendered from the CAD
Render of the printable parts from the actual CAD. Not yet printed or photographed.

Loading the CAD…

Real CAD · drag to rotate · scroll to zoomReal CAD · swipe sideways

Open risks we are working on

  • Idle demand that isn't leakage (drains, dryer purge, timers) inflates the figure; needs tagging and a zone-off test
  • VSD compressors: current-to-flow is only ±20% without a flow meter or drawdown test
  • Pressure transducer cost at qty 1 ($273) squeezes kit margin until volume or a cheaper part is qualified
  • Plant IT may block Wi-Fi; the LTE-M variant is not designed yet
  • MA40S4R receiver is not for new designs; the probe needs a second source

Design stage only: nothing on this page is for sale. Specifications and prices are targets.